5V6A 8 Channels Battery Analyzer

It is an eight-channel battery analyzer for most applications in battery testing fields such as electrode materials research, battery performance & cycle test, small-scale battery formation, capacity grading, battery pack testing and etc

Request A Quote Send E-Mail

Product Introduction
Battery Testing System
Model: BTS4000- 5 V 6 A Battery Testing System SN: CT-4008Tn -5V6A -S1/164
Items Values
Input AC AC 220V/110V ±10% / 50Hz
Input power 425 W
Resolution AD:24bit; DA: 16bit
Input impedance ≥1M Ω
 

 

Voltage

CV output range 25mV~5V
Min discharge voltage 1V for universal holder,2M line length up to 1.5V
Accuracy ± 0.05% FS
Stability ± 0.05% FS
 

 

Current

Output range/channel Range1: 0.5mA-0.1A; Range2: 0.1A-3A; Range3: 3A-6A
Accuracy ± 0.05% FS
CV cut-off current Range1: 0.2mA; Range2: 6mA; Range3: 12mA
Stability ± 0.05% FS
 

Power

Output power/channel 30 W
Stability ± 0.1% of FS
 

Time

Current response time <1ms (10%FS~90%FS)
Working step time ≤(365*24)h/step Time format-00:00:00.000(h, m, s, ms)
 

 

Data record

Data record conditions Min data record interval:100ms
Min voltage change: 10mV
Min current change: Range1: 0.2mA; Range2: 6mA; Range3: 12mA
Frequency 10Hz
 

Charge

Charge modes CC, CV, CCCV, CP
Cut-off condition Voltage, Current, Time, Capacity, Energy, -△V
 

Discharge

Discharge modes CC, CV, CCCV, CP, CR
Cut-off condition Voltage, Current, Time, Capacity, Energy
 

 

 

Pulse

Charge CC, CP
Discharge CC, CP
Min pulse width 500ms
Pulse counts Up to 32
Chg and Dschg switch A pulse working step can realize continuous charge switching, or continuous discharge switching; (Charging to discharging switch is not supported)
Cut-off condition Voltage, Time
DCIR Supported
 

Cycle

Max cycles 65535
Max steps 254
Cycle nest 3
 

 

Protection

 

 

Safety protection

● Power-failure data protection
● Offline operation mode
● User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc.
Channels feature Independent pairs of closed loop for constant
Channels control mode Independent control
Data acquisition method Kelvin connection
Noise <55dB
Database MySQL
Communication TCP/IP
Operating system Windows 7/8/10 64bit
Data export EXCEL, TXT, CSV, PDF, Plot/Graph
Min. disk drive 500GB
Communication port Ethernet port
Leak Current <5μA
Channels per unit 8
Operation and storage environment requirement
Items Values
Operation environment temperature 0℃~40℃ (When the temperature is 25±10℃, the accuracy offset caused by temperature is less than 50ppm /℃)
Storage environment temperature -10℃~50℃
Operation environment humidity ≤70% RH(no moisture condensation)
Storage environment humidity ≤80% RH(no moisture condensation)
Clamps and dimensions
Items Values
Clamps pictures

(Pictures just for reference)

OR
Dimensions(W*D*H)(mm) 3U19”,483*404*130(mm)
Tester pictures          
Picture for Reference Only, take the material object as the standard.