Categories
Latest Products
It is an eight-channel battery analyzer for most applications in battery testing fields such as electrode materials research, battery performance & cycle test, small-scale battery formation, capacity grading, battery pack testing and etc
Battery Testing System | |||||||||||
Model: | BTS4000- | 5 | V | 6 | A | Battery Testing System | SN: | CT-4008Tn | -5V6A | -S1/164 | |
Items | Values | ||||||||||
Input AC | AC 220V/110V ±10% / 50Hz | ||||||||||
Input power | 425 W | ||||||||||
Resolution | AD:24bit; DA: 16bit | ||||||||||
Input impedance | ≥1M Ω | ||||||||||
Voltage |
CV output range | 25mV~5V | |||||||||
Min discharge voltage | 1V for universal holder,2M line length up to 1.5V | ||||||||||
Accuracy | ± 0.05% FS | ||||||||||
Stability | ± 0.05% FS | ||||||||||
Current |
Output range/channel | Range1: 0.5mA-0.1A; Range2: 0.1A-3A; Range3: 3A-6A | |||||||||
Accuracy | ± 0.05% FS | ||||||||||
CV cut-off current | Range1: 0.2mA; Range2: 6mA; Range3: 12mA | ||||||||||
Stability | ± 0.05% FS | ||||||||||
Power |
Output power/channel | 30 | W | ||||||||
Stability | ± 0.1% of FS | ||||||||||
Time |
Current response time | <1ms (10%FS~90%FS) | |||||||||
Working step time | ≤(365*24)h/step Time format-00:00:00.000(h, m, s, ms) | ||||||||||
Data record |
Data record conditions | Min data record interval:100ms | |||||||||
Min voltage change: 10mV | |||||||||||
Min current change: Range1: 0.2mA; Range2: 6mA; Range3: 12mA | |||||||||||
Frequency | 10Hz | ||||||||||
Charge |
Charge modes | CC, CV, CCCV, CP | |||||||||
Cut-off condition | Voltage, Current, Time, Capacity, Energy, -△V | ||||||||||
Discharge |
Discharge modes | CC, CV, CCCV, CP, CR | |||||||||
Cut-off condition | Voltage, Current, Time, Capacity, Energy | ||||||||||
Pulse |
Charge | CC, CP | |||||||||
Discharge | CC, CP | ||||||||||
Min pulse width | 500ms | ||||||||||
Pulse counts | Up to 32 | ||||||||||
Chg and Dschg switch | A pulse working step can realize continuous charge switching, or continuous discharge switching; (Charging to discharging switch is not supported) | ||||||||||
Cut-off condition | Voltage, Time | ||||||||||
DCIR | Supported | ||||||||||
Cycle |
Max cycles | 65535 | |||||||||
Max steps | 254 | ||||||||||
Cycle nest | 3 | ||||||||||
Protection |
Safety protection |
● Power-failure data protection | |||||||||
● Offline operation mode | |||||||||||
● User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc. |
Channels feature | Independent pairs of closed loop for constant | ||
Channels control mode | Independent control | ||
Data acquisition method | Kelvin connection | ||
Noise | <55dB | ||
Database | MySQL | ||
Communication | TCP/IP | ||
Operating system | Windows 7/8/10 64bit | ||
Data export | EXCEL, TXT, CSV, PDF, Plot/Graph | ||
Min. disk drive | 500GB | ||
Communication port | Ethernet port | ||
Leak Current | <5μA | ||
Channels per unit | 8 | ||
Operation and storage environment requirement | |||
Items | Values | ||
Operation environment temperature | 0℃~40℃ (When the temperature is 25±10℃, the accuracy offset caused by temperature is less than 50ppm /℃) | ||
Storage environment temperature | -10℃~50℃ | ||
Operation environment humidity | ≤70% RH(no moisture condensation) | ||
Storage environment humidity | ≤80% RH(no moisture condensation) | ||
Clamps and dimensions | |||
Items | Values | ||
Clamps pictures
(Pictures just for reference) |
OR | ||
Dimensions(W*D*H)(mm) | 3U19”,483*404*130(mm) | ||
Tester pictures | |||
Picture for Reference Only, take the material object as the standard. |